Laboratory centrifuge refrigrated micro, table top, industrial centrifuge india

Centrifuge , Autoclave BOD Incubator shaker

Shaker

Growth Chamber

Autoclave/Sterilzer

Freezing & Cooling

Mortuary Chamber

ICE Maker/Flaker

Incubator

Heating Cooling Baths

Freez Drying Equipment

Oven

Furnace

Centrifuge

Homogenizer

Gene Gun

HPLC System

Gas Chromatography

FT-IR Spectrometer

Atomic Absorption

Micropipette

Gel Documentation

Spectrophotometer

Electrophoresis Unit

Clean Room Equipments

Laboratory PCR

Microscopes

 
 
Biotechnologies Inc
Phone: +91-9811701133
Email: bio_tin@yahoo.com
info@biotechnologiesinc.com
www.biotechnologiesinc.com
 
Manufacturer Supplier of Laboratory Centrifuge, industrial centrifuge, table top centrifuge, oil centrifuge from india  

Spectrophotometer

 
As a leading manufacturer and exporter of laboratory equipment our products Spectrophotometer are widely used in research centers and major universities. All these products are durable as well as precise and also cost effective. Our wide range includes:
 

Bio Gene™ BTI 3000 SCANNING SPECTROPHOTOMETER

 

FEATURES

    • Fixed or variable slits (bandwidths);
    • Sealed and solvent-resistant tactile keypad with alpha-numeric entry for user file names and user entry of units;
    • Pre-aligned deuterium lamp for essay lamp replacement. Lamp usage and the status of the lamps may be monitored;
    • Data Download-to-PC software for stand-alone models (optional);
    • Online software upgrade capability via internet (for stand-alone models);
    • Full A4 print-out of graphs and tables of results with popular inexpensive printers such as HP or Epson DeskJet;
    • Real-time clock for date and time stamping of results.
spectrophotometer bti3000

SPECIFICATION

Model

BTI-3000

Wavelength Range

190-1100nm

Spectral Bandwidth

4nm

Optical System

Single Beam , Grating 1200 lines/mm

Wavelength Accuracy

¡À0.5nm

Wavelength Repeatability

0.3nm

Scanning Speed

Hi, MED. LOW. MAX. 3000nm/min

Photometric Accuracy

0.3%T

Photometric Repeatability

0.2%T

Photometric Range

0-200%T , -0.3 - 3A £¬0-9999Conc.

Stray Light

0.05%T@220 £¬340nm

Stability

0.002A/h @500nm

Display

5 inches LCD(320*240 dots)

Baseline Flatness

0.002A(200-1000nm)

Sample Compartment

Accommodates 1000nm path-length

¡¡

curette with optional holder

Light Source

Halogen  Deuterium lamp(pre-aligned)

Output

USB Port Parallel Port(printer)

Power Requirement

AC 220/50Hz or AC 110/60Hz

Dimensions(W*D*H)

480x360x160mm

Weight

16kg

 


 
 

Bio Gene™ BTI 3100 SCANNING SPECTROPHOTOMETER

 
spectrophotometer bti 3100

FEATURES

    • Fixed or variable slits (bandwidths);
    • Sealed and solvent-resistant tactile keypad with alpha-numeric entry for user file names and user entry of units;
    • Pre-aligned deuterium lamp for essay lamp replacement. Lamp usage and the status of the lamps may be monitored;
    • Data Download-to-PC software for stand-alone models (optional);
    • Online software upgrade capability via internet (for stand-alone models);
    • Full A4 print-out of graphs and tables of results with popular inexpensive printers such as HP or Epson DeskJet;
    • Real-time clock for date and time stamping of results.

SPECIFICATION

Model

BTI-3100

Wavelength Range

190-1100nm

Spectral Bandwidth

2nm

Optical System

Single Beam , Grating 1200 lines/mm

Wavelength Accuracy

0.5nm

Wavelength Repeatability

0.3nm

Scanning Speed

Hi, MED. LOW. MAX. 3000nm/min

Photometric Accuracy

0.3%T

Photometric Repeatability

0.2%T

Photometric Range

0-200%T , -0.3 - 3A £¬0-9999Conc.

Stray Light

0.05%T@220 £¬340nm

Stability

0.002A/h @500nm

Display

5 inches LCD(320*240 dots)

Baseline Flatness

0.002A(200-1000nm)

Sample Compartment

Accommodates 1000nm path-length

¡¡

curette with optional holder

Light Source

Halogen  Deuterium lamp(pre-aligned)

Output

USB Port Parallel Port(printer)

Power Requirement

AC 220/50Hz or AC 110/60Hz

Dimensions(W*D*H)

480x360x160mm

Weight

16kg

 

Bio Gene™ BTI 3200 SCANNING SPECTROPHOTOMETER

FEATURES

    • Fixed or variable slits (bandwidths);
    • Sealed and solvent-resistant tactile keypad with alpha-numeric entry for user file names and user entry of units;
    • Pre-aligned deuterium lamp for essay lamp replacement. Lamp usage and the status of the lamps may be monitored;
    • Data Download-to-PC software for stand-alone models (optional);
    • Online software upgrade capability via internet (for stand-alone models);
    • Full A4 print-out of graphs and tables of results with popular inexpensive printers such as HP or Epson DeskJet;
    • Real-time clock for date and time stamping of results.
spectrophotometer 3200

SPECIFICATION

Model

BTI-3200

Wavelength Range

190-1100nm

Spectral Bandwidth

1.8nm

Optical System

Single Beam , Grating 1200 lines/mm

Wavelength Accuracy

0.3nm

Wavelength Repeatability

0.2nm

Scanning Speed

Hi, MED. LOW. MAX. 3000nm/min

Photometric Accuracy

0.3%T

Photometric Repeatability

0.15%T

Photometric Range

0-200%T  0.3 - 3A £¬0-9999Conc.

Stray Light

0.05%T@220 x 340nm

Stability

0.002A/h @500nm

Display

5 inches LCD(320*240 dots)

Baseline Flatness

0.002A(200-1000nm)

Sample Compartment

Accommodates 1000nm path-length

¡¡

curette with optional holder

Light Source

Halogen  Deuterium lamp(pre-aligned)

Output

USB Port Parallel Port(printer)

Power Requirement

AC 220/50Hz or AC 110/60Hz

Dimensions(W*D*H)

600 x 450 x 200mm

Weight

20kg

Bio Gene™ BTI- (3300) SCANNING SPECTROPHOTOMETER

spectrophotometer 3300

FEATURES

    • Fixed or variable slits (bandwidths);
    • Sealed and solvent-resistant tactile keypad with alpha-numeric entry for user file names and user entry of units;
    • Pre-aligned deuterium lamp for essay lamp replacement. Lamp usage and the status of the lamps may be monitored;
    • Data Download-to-PC software for stand-alone models (optional);
    • Online software upgrade capability via internet (for stand-alone models);
    • Full A4 print-out of graphs and tables of results with popular inexpensive printers such as HP or Epson DeskJet;
    • Real-time clock for date and time stamping of results.

SPECIFICATION

Model

BTI-3300

Wavelength Range

190-1100nm

Spectral Bandwidth

1.0nm

Optical System

Single Beam , Grating 1200 lines/mm

Wavelength Accuracy

0.3nm

Wavelength Repeatability

0.2nm

Scanning Speed

Hi, MED. LOW. MAX. 3000nm/min

Photometric Accuracy

0.3%T

Photometric Repeatability

0.15%T

Photometric Range

0-200%T  0.3 - 3A £¬0-9999Conc.

Stray Light

0.05%T@220 x 340nm

Stability

0.002A/h @500nm

Display

5 inches LCD(320*240 dots)

Baseline Flatness

0.002A(200-1000nm)

Sample Compartment

Accommodates 1000nm path-length

¡¡

curette with optional holder

Light Source

Halogen  Deuterium lamp(pre-aligned)

Output

USB Port Parallel Port(printer)

Power Requirement

AC 220/50Hz or AC 110/60Hz

Dimensions(W*D*H)

600 x 450 x 200mm

Weight

20kg


 
Please select your language
English Français Españo
Deutsch Italiano Portugues
   
 
Copyright © Biotechnologies Inc., All Rights Reserved (Terms of Use)
Developed by DEPL Technologies
Industrial Centrifuge, oil centrifuge, laboratory centrifuge, refrigerated centrifuge Manufacturer india