Industrial Sterilizer

Manufacturer autoclave

Autoclave/Sterilizer, Autoclave BOD Incubator shaker

PCR

Bioreactor/Fermenter

Shaker

Growth Chamber

Autoclave/Sterilzer

Freezing & Cooling

ICE Maker/Flaker

Incubator

Heating Cooling Baths

Freez Drying Equipment

Oven

Furnace

Centrifuge

Homogenizer

Gene Gun

HPLC System

Gas Chromatography

FT-IR Spectrometer

Atomic Absorption

Micropipette

Gel Documentation

Spectrophotometer

Electrophoresis Unit

Clean Room Equipments

Laboratory PCR

Microscopes

Partner Sites
 
 
Biotechnologies Inc
Phone: +91-9811701133
Email: bio_tin@yahoo.com
info@biotechnologiesinc.com
www.biotechnologiesinc.com
 
Laboratory PCR
Manufacturer
indian supplier
Manufacturer Supplier of Autoclave Sterilizer India, Shaker, Autoclave, Humidity Chamber and Lab Shaking Machine.  

Autoclave/Sterilizer

 
As a leading manufacturer and exporter of laboratory equipment our products autoclave, Sterilizer, BOD incubator, micropipette, deep freezer Industrial Autoclave, Autoclave Equipemts, Sterlizers, Incubator, Bioreactor, Laboratory, shaker are widely used in research centers and major universities. All these products are durable as well as precise and also cost effective. Our wide range includes:
 

Medical Autoclave Model: BTI-sjy Series

 

Bio Gene sterilizers are manufacturerd to comply to European class B standard, this sterilizer also pass the BOWIE and DISK Test and lelix tests for detection of steam & pentration as well.
Our Setrilizers have function for three step pre vacuum drying and depth of pre vacuum with 0.85 bar pressure.
The residual humidity is well below <0.2.
There improved design with B class porocity and hollow tube ensures removal of internal air even at hollow instruments, the steam at high temperature is evenly distributed all over the chamber.
Bio Gene unique disign of this high tech sterilizer also ensure 100% sterilization of cotton as well apart from the instruments used.
The sterilizers are capable to give data output through USB port or can be coupled to a mini printer. The microprocessor based software is easy and operator friendly and menu driven to give ease in operations.

autoclave sterilizer
SJY-12 and SJY-8
Model
Voltage
(V/Hz)
Power
(W)
Capcity
(L)
Chamber Capacity
(mm)
Packing Size
(mm)
Weight
(KG)
SJY-12
220/50
1500
12
200X368
660X550X560
38
SJY-8
220/50
1100
8
170X320
660X550X560
35

Specifications:

Capacity: 12L OR 8L
sterilizing temperature: 121℃,134℃
Special function: Kill the AIDS (HIV), hepatitis B (HBV) mad cow virus and Bacillus
Dry procedure: vacuum drying
Display: LED
Test program -------
sterilizing data : Print by optional external mini-printer or download USB port
Safety Features: Safe Valve;Double-control lock system and self-test alam system
water supply system : Two water tanks inside.capacity of reservoirs(3.5L fresh water and 5 liter waste water reservoirs)
Voltage: 220V±10%
power: 8L:1100W, 12L:1500W
instrument containers: 5-layer activity pallet rack with 3 trays
Chamber size : 200mm*368mm(12L);170mm*320mm(8L)
Net weihgt : 38Kg(12L);35Kg(8L)

Features:


1.Steam generator and bolier heating separated.
We adopt the Steam generator to produce steam, which is mounted seperatly with controlled steam indent, so that we can manipulate the speed and volume of steam generated, reducing the water consumption,and also improved the lifetime of heating circle because of the lower temperature of bolier.

2.The material of Lid safe&reliable
Imported 2mm SU304 stainless steel Lid is used to ensure safety when the inside chamber have a higher pressure and also this will avoid the second times pollution which casued by the corrosion from the Lid.

3.Advantages of the control system
Our Sterilizers are a result of Research & Developent for unique temperature and pressure control technology to ensure the Positive and negative temperature of every two points inside chamber which is less than 0.5℃, guarantee complete sterilization。
4.The reliability of measurement accuracy
The measurement accuracy of temperature:0.1℃,The measurement accuracy of pressure:0.001bar。

5.The safty of double-control lock structure
Use latest Machinery and electronic double-control lock structure,to be sure the safty durning the operation time.

6. Low enough vacuum ability
Use double-head vacuum pump,let the each pulse vacuum process achieve low enough vacuum, guarantee complete sterilization。

7. Automatical & manual adjust of the parameters of temperature sensor
The adjust of parameters is automatic, and manual adjustment is also available.this way we can ensure the machine can work in different atmospheric environments

8. Multilanguage are optional,Easy to operate
The users can find the language according his requestes, easily.

9. Broad ventilation window design, convenience& fast of heat radiation

 
 
Please select your language
english English dutch Français biotechnologies inc Españo
biotech
french Deutsch areabic Italiano biotech india Portugues
   
 
Copyright © Biotechnologies Inc., All Rights Reserved (Terms of Use)
Industrial Sterilizer autoclave