Horizontal Rectangular Double Door Autoclave
Enquiry
Submit

Autoclave ISO, 13485, CMDCAS, FBAS, GMP,  21 CFR PART  II NIST, OM-CP-AVS140-1/6.

BioGene understands the need for Sustainable Quality life and Pollution free Environment.

The Pressure on the Industries, Hospitals Pharma & Chemical Industries to properly manage the quality of life and developing sustainable fitness by generating vaccines and Inoculation. Secondly In today’s world, Hospital, Medical & Industrial waste Management is a big responsibility as well . BioGene makes conscious efforts and produced dedicated sterilizer autoclaves for complete sterile vaccine and Inoculation of medical, Hospital waste Sterilization under strict guidelines of FDA, GMD NIST OM-CP-ARS-140=186.

Our Hospital Medical Autoclaves Deactivate Biomedical waste, Aphis Micro organism Viruses, Bacteria, effectively by using pressurized saturated steam controlled through microprocessor Based dedicated sterilization cycles in the Double Door Autoclaves. 

BioGene Sliding Double Door Autoclaves are thus an eminent choice in development of vaccines approved by world Health Organisations and central Pollution Board.

  • Applications
  • Features
  • Control
  • Construction
  • Specification

Hospital Waste, Medical & surgical Waste, Industrial Bio Hazard sterilization Non sterile to sterile movement.

  • Double Door
  • Dry and wet sterilization
  • Confirm to EMD 93/42/EEC
  • PID Controls
  • Graphic & Logs
  • Radial Lock
  • On Line Printer
  • Touch Screen
  • Digital Temperature
  • Digital Timer
  • Pressure control
  • Dry wet cycles
  • Alarm
  • Over Temperature
  • Pressure Cut OFF Device
  • Autoclave confirms to: ISO 13485, CMDCAS, FBAS, GMP. 21 CFR PART  II software, NIST, OM-CP-AVS140-1/6.

 

  • Triple walled
  • Stainless steel 316 / 304.
  • Microprocessor Based Controls
  • Steam Generator 304/316
  • Vacuum Breaker
  • Solenoid valves
  • Automatic water cut off device
  • Trolley, carriage, Trays
  • Digital Temperature, Time, Controls
  • Pressure controls.
MODEL BTI-RA-DD10 BTI-RA-DD12 BTI-RA-DD16 BTI-RA-DD55
Make BIO GENE
Technical Matrix For Lab
Temperature range 115ºC-121ºC
(Optional 132 ºC and above)
Trays 2
Temperature Sensor PT 100
WORKING PRESSURE 15 to 22 p.s.i
Inner chamber Stainless Steel Sheet (SS-304)
Outer chamber Stainless Steel Sheet (SS-316)
Temperature Controller Microprocessor Based Programmable Controller
Heat Load 6 KW/ 9KW/ 9KW/ 9KW
Nominal Voltage 220-230 Volts, 50Hz Single Phase
SIZE 450 x 450 x 900mm 600 x 600 x 900mm 600 x 600 x 1200mm 900 x 900 X 1800mm
CAPACITY-LTRS 180 LTR 340 LTR 450 LTR 1550 LTR