Horizontal Cylindrical Autoclave – Industrial Grade Sterilizer

Bio Gene Horizontal Cylindrical Autoclave help attain sterilization by disinfection the Biological materials from Viruses, Bacteria using saturated steam pressured in combination of time Duration, Temperature thereby eradication. The Micro organisms spares much faster due to dedicated dry or wet cycles by programming the Slow or fast exhaust fine tuned to deliver fully sterilized Media glass ware etc. or Hospital or Industrial Waste.

Bio Gene® HORIZONTAL AUTOCLAVE CYLINDRICAL is widely used in Research Centers, Major Universities, Pharma, Biotech, Medical research, Hospital, Diagnostics, Agriculture science, Pharmacology, Immunology, genetics, Bioengineering Biotechnology, Microbiology, Botany, Zoology etc.

 

  • Ersatile usage.
  • Ergonomic Design
  • Energy Efficient
  • Double Safety Radial Locking Arrangement
  • Double Safety Valve Protection
  • Hydraulic Testing Upto 2.5 times the working pressure
  • Calibration And Protocol Documentation
  • Microprocessor based controls.
  • Data Logging System (Optional) 

 

  • Microprocessor Based Programmable controls
  • Temperature: 105 to 121/134ºC.
  • PRESURE RANGE: 15 -22psi/32psi
  • Time :- 0-99/999 Min
  • Door Lock :- lockable
  • Blower speed : ON/OFF
  • Alarm : Temperature Timer
  • Sterilization : Cycle
  • Process: Start. End
  • Air : Class 100
  • EN: 60601 : 1
  • EMD : 93/42/EEC

 Bio Gene HORIZONTAL CYLINDRICAL Autoclave is double walled units. The inner chamber is made of heavy gauge stainless steel sheet of SS-304 grade. The Outer body of our Autoclave is constructed out of thick Sheet duly pre-treated with primers and rusts proofing and painted with long lasting stove enamel or elegantly powder coated. 

Bio Gene Autoclaves are air insulated from inside, however we may incorporate mineral glass wool insulation if the customer desires so. The strong lid constructed out of thick steel plate which is lined from inside with Stainless steel sheet of Stainless Steel -304 grade has a double safety radial locking arrangement , which ensures an easy and smooth opening and closing operation for all Bio Gene CYLINDRICAL autoclaves are ideally suited for hospitals and research labs where safety is the first priority of the users, since it is equipped with a double safety steam release valve. At the same time we test all our autoclaves for up to 2.5 times the standard working pressure to ensure maximum safety and protection from any unfortunate incident... All our CYLINDRICAL autoclave is supplied complete with pressure gauge, pressure release valve and stainless steel basket as a standard feature.

MODEL BTI-HCA-119 BTI-HCA-175 BTI-HCA-235 BTI-HCA-335 BTI-HCA-420 BTI-HCA-500 BTI-HCA-800
Make BIO GENE
Technical Matrix For Lab
Temperature Sensor PT 100
Basket 1
Temperature range 115ºC-121ºC
Temperature Controller Microprocessor Based Programmable Controller
WORKING PRESSURE 15 to 22 p.s.i
INNER CHAMBER Stainless Steel Sheet
Outer body Covered Mild steel
Heat Load 6 KW/ 9KW/ 10KW/ 12KW
Nominal Voltage 220-230 Volts, 50Hz Single Phase
SIZE 450 x 750mm 500 x 900mm 500 x 1200mm 600 x 1200mm 600 x 1500mm
CAPACITY 119 LTR 175 LTR 235 LTR 335 LTR 420 LTR 500 LTR 800 LTR

A horizontal cylindrical autoclave is a pressure vessel designed to sterilize, cure, or process materials using a combination of steam, heat, and pressure. It is widely used in industries such as healthcare, rubber and composite manufacturing, aerated concrete (AAC) production, and food processing. The horizontal orientation allows for easy loading and unloading of long or bulky materials, making it ideal for large-scale or continuous production environments.

Customer safety is a top priority, so these autoclaves are equipped with multiple safety mechanisms including pressure relief valves, interlocking door systems that prevent opening under pressure, temperature and pressure sensors with automatic shutoff, and emergency venting systems. Many models also include digital monitoring panels that provide real-time alerts if operating parameters exceed safe limits, ensuring both operator protection and process reliability.

Routine maintenance is essential for consistent performance and longevity. This typically involves regular inspection of door seals and gaskets, checking pressure gauges and safety valves for accuracy, cleaning the interior chamber to prevent residue buildup, and lubricating moving parts such as door hinges and locking mechanisms. It is recommended to follow a scheduled maintenance plan as specified by the manufacturer and to keep a maintenance log for compliance and warranty purposes.

Horizontal cylindrical autoclaves come in a wide range of sizes and capacities to suit different production needs, from small batch units used in laboratories or clinics to large industrial vessels capable of processing several cubic meters of material at once. Customers can typically choose custom diameter and length configurations, along with tailored loading systems such as trolleys or rail-mounted carts, depending on the specific application and space available in the facility.

After-sales support usually includes installation assistance, operator training, and access to technical support for troubleshooting. Most autoclaves come with a standard warranty covering manufacturing defects and key components such as the pressure vessel, control system, and safety devices. Extended service contracts and spare parts availability are often offered as well, ensuring the equipment remains operational with minimal downtime throughout its service life.
×