Cold Laboratory Chambers for Precise Temperature-Controlled Storage

BioGene Cold Lab Chambers are precision-engineered cold storage solutions designed to maintain stable, low-temperature environments for sample preservation, stability testing, and temperature-sensitive research. Manufactured and exported by Biotechnologies Inc., these chambers offer accurate temperature control ranging from 2°C to 8°C or lower, with uniform airflow, digital PID control, and optional humidity regulation. Ideal for pharmaceutical labs, life sciences research, clinical diagnostics, and food quality testing, BioGene cold chambers are built with durable construction, GMP compliance, and low-noise, energy-efficient performance. Designed in India and trusted globally, they meet the evolving demands of cold storage in research and industry.

  • Ideal for cold storage of temperature-sensitive samples in labs and hospitals
  • Used in pharmaceuticals, life sciences, research labs, biotech, and diagnostics
  • Suitable for storing enzymes, reagents, culture media, blood, and vaccines
  • Useful in food tech and environmental testing under cold conditions

    (Lab chiller provide the power failure Alarm, probe failure alarm, Instrument failure alarm, Open door alarm, Contact to remote alarm Etc.)
  • Temperature range typically from +2 °C to +8 °C or custom-configured
  • Digital temperature controller with high accuracy
  • Forced air circulation for uniform temperature distribution
  • Visual and audio alarms for temperature deviation and door ajar
  • LED internal lighting, lockable doors, and caster wheels
  • Flexible shelving for easy storage.
  • Automatic door closing.
  • Stainless steel inside/outside.
  • High temperature/door Alarm
  • Frost fee cold lab chamber.
  • Automatic door closing and Lock.
  • Reversible door.
  • Digital temperature display.
  • Adjustable shelves (Chiller) Freezing shelves.
  • Air Sliding Door
  • Self closing door 900C stop.
  • Ambient Temperature display.
  • Digital micro processor controller with Digital display(Optional )
  • 100% Space utilization.
  • Digital micro processor controller with display.
  • Flexi shelving for better space utilization.
  • Battery level indication
  • Precise temperature.
  • Look for Ensuring security of Medicines /Samples.
  • Castors for easy Mobility of Equipment.
  • Heavy duty industrial grade hermitically sealed compressor.
  • Auto cycle in case of probe failure available.
  • Internal construction made of Stainless steel.
  • External material cold rolled steel coated with Anti-bacteria powder.
  • Refrigeration Type: Forced air refrigeration system
  • Unique body design and Mono-assembly foaming.
  • Microprocessor-based digital control system
  • High/low temperature alarms with alert memory
  • Optional GSM alert or remote monitoring system
  • Programmable setpoints with data logging support
  • Inner chamber: Stainless steel
  • Outer body: Powder-coated GI sheet or optional stainless steel
  • High-density PUF insulation (approx. 60–80 mm)
  • Adjustable/removable shelves or trays
  • Solid doors with silicone gaskets and vacuum release port
MODEL BIT
DESCRIPTION Double door Refrigerator
CAPACITY  Liter 300 - 1500 Liter
CONTROL SYSTEM Microprocessor control & Large
TEMPERATURE RANGE +1°C -   + 8°C
FREQUENCY 50/60HZ
TEMPERATURE ACCURACY 0.1 °C
DIGITAL DISPLAY YES
LOCK YES
WHEELS YES
NO OF DOORS 2 /Solid
Refrigerant RS 232 Interface, CFC Free
Power supply AC 220 V ±10%
Defrost Auto defrost
Condenser and Evaporator High Efficiency air cooled condenser, made of copper
Noise level 43dB

A Cold Lab Chamber is a temperature-controlled enclosure designed for laboratories that need to store, test, or preserve samples, materials, or equipment under stable low-temperature conditions. It is commonly used for stability testing, sample preservation, pharmaceutical research, biological storage, and material behavior studies at sub-ambient temperatures.

Most Cold Lab Chambers can maintain temperatures ranging from around -20°C to +10°C, though specialized units can go as low as -40°C or lower depending on the model and intended application. The exact range depends on the compressor system, insulation quality, and chamber size, so it's best to check the specific model's technical datasheet before purchase.

Temperature accuracy is maintained through a combination of high-precision sensors, digital PID controllers, and forced-air circulation systems that ensure even cooling throughout the chamber. Regular calibration, proper door sealing, and avoiding overloading the chamber with samples also help maintain consistent temperature uniformity across all shelves and zones.

Routine maintenance includes cleaning the condenser coils, checking door gaskets for wear, defrosting if applicable, verifying calibration of temperature sensors, and ensuring proper ventilation around the unit. It's recommended to schedule professional servicing at least once or twice a year to prevent compressor strain and extend the chamber's operational lifespan.

Cold Lab Chambers are versatile enough for both purposes; many labs use them for long-term sample storage as well as short-term stability or environmental testing. However, for long-term storage of sensitive biological or pharmaceutical materials, it's important to choose a chamber with reliable backup power options and continuous monitoring alarms to prevent temperature excursions that could compromise sample integrity.
×